S01 - Sivaper Thermal Insulation Plaster
Applicable on the walls of the buildings. It consist of expanded perlite and cement as well as some special additives that provide workability, water repellency, adhesion, etc. Provides thermal insulation, sound insulation, fire resistance, lightweight structures and breathable walls which prevents mold formation inside the buildings because of humidity. It is a very lightweight material while most of the wall plasters in the market are heavier. It can be applied on interior and exterior walls.
S02 - Sivaper Lightweight Interior Plaster
Applicable on the interior walls of the buildings. It consist of expanded perlite and cement as well as some special additives that provide workability, adhesion, etc. Provides thermal insulation, sound insulation, fire resistance, lightweight structures and breathable walls which prevents mold formation inside the buildings because of humidity. It is a very lightweight material while most of the wall plasters in the market are heavier. It can be applied on interior walls.
S03 - Sivaper Thermal Insulation Mortar for Floorings and Roofs
Expanded perlite and cement based ready mix mortar. Applicable on the floorings and roofs of the buildings. Provides thermal insulation, sound insulation, fire resistance, lightweight structures and breathable and healthy buildings.
Technical Properties
 |
| white powder |
white powder |
grey powder |
| 300 |
450 |
300 |
| 0,064 |
0,096 |
0,064 |
| N/A – Class A1 |
N/A – Class A1 |
N/A – Class A1 |
| +5 - +30°C |
+5 - +30°C |
+5 - +30°C |
| 50 lt paper bag |
50 lt paper bag |
50 lt paper bag |
| 18 lt / bag |
20 lt / bag |
12 lt / bag |
| 6 months |
6 months |
6 months |
Application
- Remove dust, small particles and traces of foreign materials from the surface
- Prepare by adding SIVAPER to a measured amount of clean water. Suitable mixing time is a few minutes. Let the composition stand for 10 minutes and mix again for half a minute and adjust the water amount if necessary.
- SIVAPER is now ready to use. When area has been covered to the desired thickness, light weight levelling tools are used in conjunction with a trowel to fill the hollows. The plaster, once sufficiently stiff, should once more be given a final smoothing to remove any high points or undulations.
- The covered area should be water up to 7 days depending on the weather conditions (i.e. hot climates)
- The thickness of the plaster is so important in order to get an efficient insulation.
Please ask for further information from
info@sivaper.com